Thermoworks 226-270 DATA TEMPERATURE RECORDER - DTR Software M Manuale Utente

Navigare online o scaricare Manuale Utente per Strumenti di misura Thermoworks 226-270 DATA TEMPERATURE RECORDER - DTR Software M. ThermoWorks 226-270 DATA TEMPERATURE RECORDER - DTR Software Manual User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - PTR/DTR

Software User ManualPTR/DTR Printing Thermometer Software

Pagina 2 - CONTENTS

10DEFINING THE LABELS AND LIMITS - DTRThe DTR has 1 input and up to four labels can be defined for use. These labels can each have their own high and l

Pagina 3

11DEFINING THE LABELS AND LIMITS – PTRThe PTR has 4 inputs. To define inputs and their high and low limits simply hover the mouse cursor over the &apo

Pagina 4 - INTRODUCTION

SAVING THE TICKET LAYOUT AND SETTINGS TO THE PCTo save the current 'Ticket layout' to the PC, along with the selected settings, click the &a

Pagina 5

13LOADING THE TICKET LAYOUT AND SETTINGS FROM THE PCTo load previously saved settings from the PC, click the 'Load' button in the 'Layo

Pagina 6 - TICKET PREVIEW

14DATA TABRETRIEVING STORED READINGS FROM THE PTR/DTRTo sort the readings by heading, click on a column header.READINGS:GET – retrieves all readings s

Pagina 7 - SELECTING A PTR/DTR

Information displayed in the list are Reading Number (#), Date/Time, Reading, High Limit, Low Limit and Label. Readings can be sorted in ascending or

Pagina 8 - SELECTING AN IMAGE

16EXPORTING READINGS TO EXCEL FILEDownloaded readings can be exported to an 'Excel' file. To do so, click on the 'Export' button in

Pagina 9 - CHANGING THE DATE/TIME FORMAT

17ADVANCED SETTINGS TAB – PTRAUTO-OFFTo maximise battery life, the DTR can be set up to switch off automatically after given period of time when idle.

Pagina 10

18MODE OPTIONS PTR instrument has three modes of operation: On Demand printing, Logging and Log Summary. The set-up of these is achieved using the &a

Pagina 11

19overwrite the oldest data in memory but selecting the appropriate option in the 'Data storage' section of the Advanced tab.TICKET HEADINGS

Pagina 12

2CONTENTSIntroduction 4To install the PTR/DTR PC software 4General tab 6Device 6Settings 6Status 6Ticket preview 6Layout 7Selecting a PTR/DTR 7Get

Pagina 13

20TICKET HEADINGS – LOGGING MODEREADING TRIMEach input can have a ±2.0 °C (3.6 °F) trim value applied to it. This is to allow for variations in indivi

Pagina 14

21The trim operation can be password protected. To set a password the user must have administrator privileges for the computer.ADVANCED SETTINGS TAB

Pagina 15

22NUMBER OF COPIES TO BE PRINTED USING THE REMOTE BUTTONTo increase or decrease the number of copies to be printed when pressing the remote button cli

Pagina 16

23RESETTING THE ADVANCED SETTINGS TO ‘DEFAULT’ VALUESTo reset all advanced settings ('Operation of the remote button', 'Auto-off',

Pagina 17 - AUTO-OFF

16.10.121762 W. 20 S. #100, Lindon, UT 84042Ph: 801-756-7705 Fax: 801-756-8948www.thermoworks.com

Pagina 18 - 'SUMMARY' MODE

3Erasing readings from the devise 15Exporting readings to excel file 16Advanced tab - PTR 17Auto-off 17Mode options

Pagina 19 - 'LOGGING' MODE

4INTRODUCTIONThe PTR/DTR printing thermometer PC software is used to configure the thermometer and retrieve stored readings from it.The PTR has 4 input

Pagina 20 - READING TRIM

The program files will be installed by default to...''C:\Program Files\ETI Ltd\Printing Temperature Recorder\'' (Recommended).Th

Pagina 21 - OPERATION OF THE PROBE BUTTON

GENERAL TABDEVICEWhen working on ticket layouts without a device connected to the PC select DTR or PTR. When devices are plugged into the PC USB sock

Pagina 22 - TICKET HEADINGS - DTR

7LAYOUTSAVE – saves the current ticket layout to the PC.LOAD – loads saved ticket layout from the PC.DELETE – deletes a saved ticket layout.CLOSE

Pagina 23

8CONFIGURING THE PTR/DTRTo configure the PTR/DTR with the current ticket layout and settings, click the 'Set' button in the 'Settings&ap

Pagina 24 - 16.10.12

To erase the existing image, click the 'X' button at the top right corner of the image area. EDITING USER FIELDSA DTR ticket has eight u

Commenti su questo manuale